Advanced Ultraviolet Detection Solutions for Scientific and Diagnostic Applications
Ultraviolet (UV) analysis plays a critical role in modern laboratories, particularly in molecular biology, forensic science, and biochemical diagnostics. Among the wide array of instruments available, the Darkroom UV Analyzer with High Sensitivity offers a specialized, enclosed system that enhances the accuracy and safety of UV fluorescence visualization. Manufactured by Equilrxnlab, this analytical device is engineered to deliver precision and user protection in compact bench-scale environments.
This instrument is uniquely designed to support qualitative inspection of nucleic acids, proteins, and fluorescent markers under both short-wave and long-wave UV light. It integrates a closed darkroom system to eliminate ambient light interference, thereby ensuring high sensitivity and clarity in visualization tasks.
Key Technical Capabilities of the Darkroom UV Analyzer with High Sensitivity
The Darkroom UV Analyzer with High Sensitivity is defined by several specifications that optimize its utility across laboratory applications. It operates with dual UV wavelengths—365 nm for long-wave exposure and 254 nm for short-wave analysis—allowing comprehensive inspection of materials that react under varying UV spectra.
The built-in darkroom design ensures maximum operator safety and analytical precision. With a compact form factor measuring 272×230×250 mm and weighing only 6 kg, the device is suitable for laboratories with space constraints yet high demands for fluorescence analysis.
Product Specifications:
- Type: Dark Box UV Analyzer
- Filter Size: 150×80 mm
- Long-Wave UV: 365 nm
- Short-Wave UV: 254 nm
- Power Supply: AC 220V/50Hz
- Power: 24W
- Lamp Life: ≥500 hours
- Dimensions: 272×230×250 mm
- Weight: 6 kg
For full technical details, view the product page at:
https://equilrxnlab.com/product/zf-20d-darkroom-type-uv-analyzer/
Practical Applications in UV-Responsive Sample Analysis
The primary advantage of the Darkroom UV Analyzer with High Sensitivity lies in its dual-wavelength UV illumination, which is essential for distinguishing between different fluorescent signals. Long-wave UV (365 nm) is commonly employed in gel documentation and DNA electrophoresis, while short-wave UV (254 nm) provides enhanced contrast for specific dye-based detections in thin-layer chromatography (TLC) and protein blotting.
Researchers and clinicians alike benefit from its enhanced sensitivity, which facilitates accurate visual recognition of trace samples. This becomes especially important in tasks involving low-abundance nucleic acid samples, fluorescence-tagged molecules, and UV-reactive forensic residues.
Explore more analytical tools in the Equilrxnlab catalog.
Benefits of Darkroom Integration in UV Analysis
One of the most notable features of this device is its enclosed darkroom format. This design effectively isolates the analysis area from ambient light, thereby preventing signal distortion and operator exposure to harmful UV radiation. This is critical for maintaining both experimental validity and safety standards in daily lab use.
The 150×80 mm filter size accommodates common gel electrophoresis trays and TLC plates, ensuring compatibility across various experimental protocols. Users can perform visual inspections without the need for external safety equipment or dedicated darkroom spaces, thereby increasing lab flexibility and reducing operational costs.
To get in touch with the technical team or request further assistance, please visit:
https://equilrxnlab.com/contact-us/
Enhancing Laboratory Workflow Through Compact, Reliable Design
The compact structure of the Darkroom UV Analyzer with High Sensitivity makes it an ideal choice for high-throughput environments, such as academic research centers, pharmaceutical labs, and forensic departments. The long lamp life (≥500 hours) and energy-efficient 24W power usage support continuous operation without frequent maintenance interruptions.
Furthermore, the unit’s standardized AC 220V/50Hz power supply allows easy integration into existing lab infrastructure, while its lightweight build facilitates mobility between workstations or collaborative spaces.
For updates on this product and others, follow Equilrxnlab’s channels:
Role of High-Sensitivity UV Analysis in Experimental Precision
In fluorescence-based methodologies, instrument sensitivity determines the resolution and contrast of visualization. The Darkroom UV Analyzer with High Sensitivity offers consistent illumination across the UV spectrum, minimizing noise and maximizing the signal-to-background ratio.
Such capabilities are particularly beneficial in experiments requiring photographic documentation or comparative sample tracking, where even minor discrepancies can affect downstream interpretation.
Whether employed for DNA quantification, forensic inspections, or thin-layer chromatography, this UV analyzer consistently supports reproducibility and confidence in scientific data.
To discover more about this reliable analytical instrument, visit the product listing:
https://equilrxnlab.com/product/zf-20d-darkroom-type-uv-analyzer/
Browse additional laboratory solutions in the Equilrxnlab catalog, or contact a technical advisor directly via the Equilrxnlab contact page.
Stay connected for demonstrations and lab content via YouTube, Instagram, and Facebook.