Explore our top lab equipment to find your perfect solution

AKGD-30L/-60℃+200℃ recirculating chiller with heater

Recirculating Chiller with Heater -60°C to 200°C, 30L Capacity

Wide-Range Temperature Control with Recirculating Chiller with Heater

The AKGD-30L/-60+200 recirculating chiller with heater delivers powerful and precise thermal regulation from -60°C to 200°C. Designed for laboratory and industrial settings, this 30L model offers ±1°C temperature stability and combines both advanced cooling and heating in a compact, air-cooled unit. It’s the ideal choice for applications requiring wide-range, high-performance temperature control.

Main Features of the Recirculating Chiller with Heater

  • Wide temperature operating range: -60°C to 200°C

  • High temperature stability: ±1°C for reliable thermal processes

  • Dual 2.25 kW air-cooled compressors for efficient cooling

  • 7.5 kW heating power for rapid temperature rise

  • Stainless steel tank and pipelines (SUS304) for corrosion resistance

  • High-capacity pump: 42 L/min flow rate and 22 bar pressure

  • Compact air-cooled structure, ideal for clean room and lab setups

  • Fully enclosed rotary compressor and reliable refrigerants (R22, R23)

This recirculating chiller with heater ensures stable and accurate temperature delivery for sensitive operations.

Technical Specifications

Model: AKGD-30L/-60+200
Temperature Stability: ±1°C
Operating Temperature Range: -60°C to 200°C
Ambient Temperature: 5–35°C
Recommended Ambient Humidity: ≤60%
Power Supply: 3-phase 380V, 50Hz
Total Power Consumption: 12.37 kW / 21.9 A
Cooling Power: 2.25 × 2 kW
Heating Power: 7.5 kW
Cooling Method: Air-cooled
Compressor Model: YM49A1G-100
Compressor Power: 3 HP
Compressor Type: Fully enclosed rotary compressor
Refrigerant: R22, R23

Cooling Capacity:
@ 100°C – 12.43 kW
@ 30°C – 11.6 kW
@ -10°C – 5.57 kW
@ -20°C – 8.69 kW
@ -30°C – 6.13 kW
@ -40°C – 7.8 kW
@ -60°C – 3.59 kW

Circulating Pump Power: 370 W
Flow Rate: 42 L/min
Pump Pressure: 22 bar
External Circulation Interface Size: DN15
Circulating Medium: Silicone oil (< 50 cSt viscosity)
Material: SUS304 stainless steel tank and piping

Compatible Equipment for Recirculating Chiller with Heater

  • Rotary Evaporators – Require stable heating and cooling for vacuum distillation

  • Glass Reactors – Depend on accurate thermal control for chemical reactions

  • Freeze Dryers – Use consistent cooling from -60°C for freeze-drying efficiency

  • Material Test Chambers – Need programmable temperature cycling for reliability tests

  • Pilot Plants – Benefit from powerful thermal flow during scale-up processing

The recirculating chiller with heater is engineered to integrate seamlessly into various thermal systems.

Why Choose This Recirculating Chiller with Heater

The AKGD-30L/-60+200 recirculating chiller with heater combines heating and cooling in a single efficient system, minimizing footprint and maximizing flexibility. It is built for consistent performance across demanding applications—from research labs to industrial pilot lines—thanks to its precision, durability, and powerful capacity.

Watch Product Demonstrations

Explore real-world performance and applications in our product demo videos. Visit our video library for more insights and demonstrations.

Explore More Recirculating Chillers with Heaters

Discover more high-performance models in our recirculating chiller with heater category designed for integrated laboratory thermal control.

We provide worldwide shipping for all laboratory equipment. Every order is carefully packaged to ensure safe delivery. If the item is in stock, it will be shipped within 3–7 business days after payment confirmation. For out-of-stock items, we will inform you of the estimated shipping time based on the specific product.

Shipping Methods: DHL, FedEx, UPS, or sea freight (depending on order size and destination)
Estimated Delivery Time:

  • Asia: 5–10 business days

  • Europe & North America: 7–12 business days

  • South America & Africa: 10–15 business days

  • Sea freight: subject to actual transit time

Tracking: A tracking number will be provided via email once the shipment has been dispatched.
Customs & Duties: Buyers are responsible for any import taxes or customs duties required by their country or region.

For bulk orderscustom packaging, or special shipping arrangements, please contact our team for personalized assistance at lab@equilrxnlab.com.

Product specifications

High Pressure Reactor Equipment Specifications
ParameterSpecifications
ModelAKGD-30L/-60+200
Temperature Stability (℃)±1
Operating Temperature Range (℃)-60~200
Ambient Temperature (℃)5~35
Best Ambient Humidity≤60%
Power Supply3PH/380V/50HZ
Total Power (kW/A)12.37/21.9
Cooling Power (kW)2.25 x2
Heating Power (kW)7.5
Cooling MethodAir-cooled
Compressor ModelYM49A1G-100
Compressor Power (HP)3
RefrigerantR22,R23
TypeFully Enclosed Rotary Compressor
Cooling Capacity (kW) @ 100℃12.43KW
Cooling Capacity (kW) @ 30℃11.6KW
Cooling Capacity (kW) @ -20℃8.69KW
Cooling Capacity (kW) @ -10℃5.57KW
Cooling Capacity (kW) @ -40℃7.8KW
Cooling Capacity (kW) @ -30℃6.13KW
Cooling Capacity (kW) @ -60℃3.59KW
Circulating Pump Power (W)370W
Circulating Pump Flow Rate (L/min)42
Circulating Pump Pressure (bar)22
External Circulation Interface SizeDN15
Heat Transfer Fluid Tank MaterialSUS304
Heat transfer fluid piping and valve materialsSUS304
Circulating MediumSilicone oil below 50cs
Internal Liquid Capacity (L)20

introduce

Application Scenarios

  • Rotary Evaporator Systems
    A recirculating chiller with heater provides stable and accurate thermal control for rotary evaporators during solvent recovery and concentration processes. Its precise temperature range from -60°C to 200°C ensures efficient evaporation under vacuum without thermal degradation.

  • Jacketed Glass Reactors
    For chemical synthesis, polymerization, and crystallization, a recirculating chiller with heater ensures precise control of reaction temperatures. It supports both heating and cooling cycles, vital for maintaining reaction kinetics and safety during exothermic or endothermic processes.

  • Pharmaceutical Process Development
    In drug formulation and pilot plant testing, temperature-sensitive ingredients and compounds require reliable control. The recirculating chiller with heater maintains consistent thermal conditions throughout testing, improving repeatability and formulation integrity.

  • Freeze Drying (Lyophilization) Pre-treatment
    Used to pre-chill and control temperature during sample preparation, the recirculating chiller with heater improves the efficiency of freeze drying by optimizing thermal load distribution and reducing preparation time.

  • Battery Testing and Material Stress Testing
    Lithium battery R&D and electronic component testing often demand thermal cycling. A recirculating chiller with heater offers programmable heating and cooling, enabling thermal profiling and durability verification under extreme temperature fluctuations.

  • Distillation and Separation Systems
    In molecular distillation or short-path distillation systems, precise thermal stability is crucial. The recirculating chiller with heater prevents overheating of delicate compounds and ensures uniform condensation during distillation.

  • Biotechnology and Enzyme Reaction Control
    Bioreactors and enzyme-related studies require narrow-range thermal conditions. The integrated chiller-heater enables steady temperature regulation to maintain optimal biological activity and reduce experimental variability.

  • Vacuum Coating and Semiconductor Equipment
    Thermal management during vacuum deposition or semiconductor fabrication processes is critical. The recirculating chiller with heater provides high flow rate and tight temperature control for precise heat removal and substrate stabilization.

  • Analytical Instruments (NMR, Mass Spec, etc.)
    For high-sensitivity instruments, temperature control affects measurement accuracy. A recirculating chiller with heater minimizes drift by maintaining constant temperature conditions for instrument chambers or sample holders.

  • Food and Cosmetic Laboratory Testing
    Emulsification, stabilization, and extraction procedures in food and cosmetic testing benefit from programmable heating/cooling. The recirculating chiller with heater improves reproducibility of results and ensures process safety.

peculiarity

Eco Cooling: Copeland & Taikang

The refrigeration system uses an American Copeland compressor and a French Taikang high-temperature resistant circulation pump, offering stable performance. It adopts eco-friendly, CFC-free refrigerants, compliant with both EU and national standards.

Safety-Certified Electrical Components

This equipment uses well-known brand electrical components that meet safety standards and can be equipped with explosion-proof distribution boxes.

Compact, High-Efficiency Brazed Plate Heat Exchanger

The refrigeration uses a fully brazed plate heat exchanger, which is space-efficient and has high heat transfer efficiency, requiring less thermal oil.

High-Efficiency Air-Cooled Condenser

Designed for superior heat dissipation and rapid cooling, our air-cooled condenser ensures optimal performance and fast temperature reduction

Scope of Application

Biopharmaceuticals

Scientific Research Experiments

Food Processing

industrial factory

Why choose us?

Factory direct sales

“Factory direct sales ensure affordability, reliability, and direct access to high-quality products.”

Reliable quality

“Reliable quality ensures trust, satisfaction, durability, and consistent performance.”

Worry free after sale

“Worry-free after-sale service ensures peace of mind and satisfaction.”

Customized service

“Customized services provide personalized solutions and tailored experiences.”

Actual Product Results at Client Locations

Explore real-world examples of our product in action at client locations, showcasing its effectiveness and performance across various applications.

Shopping Cart